New Information To Be Released About WTC 7 Collapse



A draft report explaining the collapse of World Trade Center 7 (WTC 7) should be released by the end of the year, according to the National Institute of Standards and Technology (NIST).


By CP Editorial Staff  


A draft report explaining the collapse of World Trade Center 7 (WTC 7) should be released by the end  of the year, according to the National Institute of Standards and Technology (NIST).  

NIST's investigation of WTC 7 includes an analysis that incorporates detailed information about the building's structure and construction, as well as data about fires, damage sustained from falling WTC 1 debris and other technical factors to determine its probable collapse sequence.

WTC 7 was a 47-story office building adjacent to the WTC towers (WTC 1 and 2) that collapsed following the terrorist attacks of Sept. 11, 2001. WTC 7 collapsed later that afternoon.

"We are proceeding as quickly as possible while rigorously testing and evaluating a wide range of scenarios to reach the most definitive conclusion possible," says Shyam Sunder, lead investigator for NIST. "The WTC 7 investigation is in some respects just as challenging, if not more so, than the study of the towers. However, the current study does benefit greatly from the significant technological advances achieved and lessons learned from our work on the towers."

The NIST investigation team initially worked simultaneously on both the WTC towers and WTC 7 collapses. In June 2004, the team shifted to full-time study of the towers to develop needed simulation methods and other research tools and to expedite completion of the WTC towers report. Work resumed on the WTC 7 study in October 2005.

The current NIST working collapse hypothesis for WTC 7 is described in the June 2004 Progress Report on the Federal Building and Fire Safety Investigation of the World Trade Center Disaster (Volume 1, page 17, as well as Appendix L), as follows:

    An initial local failure occurred at the lower floors (below floor 13) of the building due to fire and/or debris induced structural damage of a critical column (the initiating event) that supported a large span floor bay with an area of about 2,000 square feet;

    Vertical progression of the initial local failure occurred up to the east penthouse, as the large floor bays were unable to redistribute the loads, bringing down the interior structure below the east penthouse; and

    Horizontal progression of the failure across the lower floors (in the region of floors 5 and 7, that were much thicker than the rest of the floors), triggered by damage due to the vertical failure, resulting in a disproportionate collapse of the entire structure.

This hypothesis may be supported or modified, or new hypotheses may be developed, through the course of the continuing investigation. NIST also is considering whether hypothetical blast events could have played a role in initiating the collapse.

While NIST has found no evidence of a blast or controlled demolition event, NIST would like to determine the magnitude of hypothetical blast scenarios that could have led to the structural failure of one or more critical elements.




Contact FacilitiesNet Editorial Staff »

  posted on 7/2/2007   Article Use Policy




Related Topics: